The effect of the tear film on the results of a direct assessment of the sensitivity of the cornea
Аветисов С. Э., Сурнина З. В., Новиков И. А., Черненкова Н. А., Тюрина А. А.
Вестник офтальмологии
Т. 136, Вып. 2, С. 81-85
Опубликовано: 2020
Тип ресурса: Статья
DOI:10.17116/oftalma202013602181
Аннотация:
Attempts to find clinical application for esthesiometry are associated with studying sensitivity disorders that occur in various diseases (diabetes mellitus, keratitis of various etiologies, corneal erosion, dry eye syndrome), as well as after surgical interventions. Purpose — to evaluate the influence of the tear film on the results of direct assessment of corneal sensitivity. Material and methods. The study was conducted in a group of 20 healthy volunteers. Criteria for inclusion in the group: absence of any ocular and general systemic diseases in the anamnesis, normal indicators of tear production and stability of the tear film according to Schirmer and Norn tests. The process of testing involved a specially designed device that was used to exert a dosed force by jets of air on the frontal corneal surface and the pressure was recorded at the moment of tactile sensations and at the breakup time of tear film, as an indicator of its biomechanical stability. Results. A strong correlatio
Ключевые слова:
Corneal sensitivity; Esthesiometry; Precorneal tear film
confocal microscopy; cornea; dry eye; human; lacrimal apparatus; lacrimal fluid; Cornea; Dry Eye Syndromes; Humans; Lacrimal Apparatus; Microscopy, Confocal; Tears
Язык текста: Русский
ISSN: 2309-1282
Аветисов С. Э. Сергей Эдуардович 1950-
Сурнина З. В. Зоя Васильевна 1987-
Новиков И. А.
Черненкова Н. А.
Тюрина А. А.
Avetisov S. E`. Sergej E`duardovich 1950-
Surnina Z. V. Zoya Vasilyevna 1987-
Novikov I. A.
Chernenkova N. A.
Tyurina A. A.
The effect of the tear film on the results of a direct assessment of the sensitivity of the cornea
Текст визуальный непосредственный
Вестник офтальмологии
Издательство Медиа Сфера
Т. 136, Вып. 2 С. 81-85
2020
Статья
Corneal sensitivity Esthesiometry Precorneal tear film
confocal microscopy cornea dry eye human lacrimal apparatus lacrimal fluid Cornea Dry Eye Syndromes Humans Lacrimal Apparatus Microscopy, Confocal Tears
Attempts to find clinical application for esthesiometry are associated with studying sensitivity disorders that occur in various diseases (diabetes mellitus, keratitis of various etiologies, corneal erosion, dry eye syndrome), as well as after surgical interventions. Purpose — to evaluate the influence of the tear film on the results of direct assessment of corneal sensitivity. Material and methods. The study was conducted in a group of 20 healthy volunteers. Criteria for inclusion in the group: absence of any ocular and general systemic diseases in the anamnesis, normal indicators of tear production and stability of the tear film according to Schirmer and Norn tests. The process of testing involved a specially designed device that was used to exert a dosed force by jets of air on the frontal corneal surface and the pressure was recorded at the moment of tactile sensations and at the breakup time of tear film, as an indicator of its biomechanical stability. Results. A strong correlatio