Аннотация:
An HPLC-UV method for quantitative determination of lidocaine and miramistin in a combination wound-healing gel is reported. The method was validated for specificity, linearity, accuracy, and precision. The linear range for lidocaine hydrochloride was 0.08 – 0.12 mg/mL; for miramistin, 0.04 – 0.06 mg/mL. The linear correlation coefficients were 0.9992 and 0.9996 for lidocaine hydrochloride and miramistin, respectively. The method could be used for quantitative evaluation of lidocaine and miramistin in combination medicines. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.
Ключевые слова:
chitosan; HPLC; lidocaine hydrochloride; miramistin; wound-healing gel
gel; lidocaine; miramistin; unclassified drug; wound healing promoting agent; analytic method; Article; drug determination; high performance liquid chromatography; measurement accuracy; measurement precision; quantitative analysis; validation study
Brkich L. L. Liliana Lyubanovna 1990-
Markin P. A. Pavel Aleksandrovich 1996-
Moskaleva N. E. Natal`ya Evgenyevna 1971-
Pyatigorskaya N. V. Natal`ya Valeryevna 1965-
Brkich G. E`. Galina E`duardovna 1967-
Panov A. V.
Grin M. A.
Бркич Л. Л. Лилиана Любановна 1990-
Маркин П. А. Павел Александрович 1996-
Москалева Н. Е. Наталья Евгеньевна 1971-
Пятигорская Н. В. Наталья Валерьевна 1965-
Бркич Г. Э. Галина Эдуардовна 1967-
Панов А. В.
Грин М. А.
Development and Validation of a Method for Determining Lidocaine Hydrochloride and Miramistin in an Innovative Wound-Healing Gel
Текст визуальный непосредственный
Pharmaceutical Chemistry Journal
Springer New York Consultants Bureau
Vol.54, Issue1 P. 69-72
2020
Статья
chitosan HPLC lidocaine hydrochloride miramistin wound-healing gel
gel lidocaine miramistin unclassified drug wound healing promoting agent analytic method Article drug determination high performance liquid chromatography measurement accuracy measurement precision quantitative analysis validation study
An HPLC-UV method for quantitative determination of lidocaine and miramistin in a combination wound-healing gel is reported. The method was validated for specificity, linearity, accuracy, and precision. The linear range for lidocaine hydrochloride was 0.08 – 0.12 mg/mL; for miramistin, 0.04 – 0.06 mg/mL. The linear correlation coefficients were 0.9992 and 0.9996 for lidocaine hydrochloride and miramistin, respectively. The method could be used for quantitative evaluation of lidocaine and miramistin in combination medicines. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.