Comparative clinical and laboratory study of the force loss generated by NiTi closed coil springs [Sravnitel'noe klinicheskoe i laboratornoe...
Шаддуд А. Н., Косyрева Т. Ф.
Стоматология
Т. 97, Вып. 4, С. 45-48
Опубликовано: 2018
Тип ресурса: Статья
DOI:10.17116/stomat20189704145
Аннотация:
The purpose in this study was to compare the force decay of laboratory and clinical NiTi closed coil springs. Specimens were 30 NiTi coil springs (clinical) and 15 (laboratory in artificial saliva 36.6 ºC) springs were tested by dynamometer to evaluate force loos at different intervals: 1, 2 and 3 months of use. Data (gF) were analyzed statistically using. Clinical and laboratory data were compared to evaluate effect of the oral environment on force loss. It was observed a significant force loss of NiTi springs. NiTi springs showed force loss (13.2[%]) at 28 days of clinical use, with a further significant loss from 4-12 weeks (~21[%]); force levels remained steady thereafter. Were not statistically different in clinical and laboratory force loss data. Space was closed at an average rate of 1 mm/month.Цель исследования - сравнительное клиническое и лабораторное исследование изменений свойств потери силы NiTi-закрывающих пружин из сплава никелида титана в клинике ортодонтии и в лаборатории.
Ключевые слова:
force loss; nickel titanium closed springs; orthodontics
dental alloy; nickel; titanium; materials testing; mechanics; orthodontic wire; Dental Alloys; Materials Testing; Mechanical Phenomena; Nickel; Orthodontic Wires; Titanium
Язык текста: Русский
ISSN: 2309-5318
Шаддуд А. Н.
Косyрева Т. Ф.
Shaddud A. N.
Kosyreva T. F.
Comparative clinical and laboratory study of the force loss generated by NiTi closed coil springs [Sravnitel'noe klinicheskoe i laboratornoe issledovanie poteri sily NiTi-zakryvaiushchikh pruzhin]
Comparative clinical and laboratory study of the force loss generated by NiTi closed coil springs [Sravnitel'noe klinicheskoe i laboratornoe...
Текст визуальный непосредственный
Стоматология
Издательство Медиа Сфера
Т. 97, Вып. 4 С. 45-48
2018
Статья
force loss nickel titanium closed springs orthodontics
dental alloy nickel titanium materials testing mechanics orthodontic wire Dental Alloys Materials Testing Mechanical Phenomena Nickel Orthodontic Wires Titanium
The purpose in this study was to compare the force decay of laboratory and clinical NiTi closed coil springs. Specimens were 30 NiTi coil springs (clinical) and 15 (laboratory in artificial saliva 36.6 ºC) springs were tested by dynamometer to evaluate force loos at different intervals: 1, 2 and 3 months of use. Data (gF) were analyzed statistically using. Clinical and laboratory data were compared to evaluate effect of the oral environment on force loss. It was observed a significant force loss of NiTi springs. NiTi springs showed force loss (13.2[%]) at 28 days of clinical use, with a further significant loss from 4-12 weeks (~21[%]); force levels remained steady thereafter. Were not statistically different in clinical and laboratory force loss data. Space was closed at an average rate of 1 mm/month.Цель исследования - сравнительное клиническое и лабораторное исследование изменений свойств потери силы NiTi-закрывающих пружин из сплава никелида титана в клинике ортодонтии и в лаборатории.