Comparative analysis of the chemical composition and microstructure conformation between different dental implant Bone Drills
Marenzi G., Sammartino J. C., Scherillo F., Rengo C., Rosa A. D., Graziano V., Spanyuolo D.
Materials
Vol.12, Issue11, P. 1866
Опубликовано: 2019
Тип ресурса: Статья
Аннотация:
Background: Hardness is considered an important parameter for evaluating the clinical performance of dental implant bone drills. It is connected to the chemical composition, microstructure conformation and manufacture of the surgical drills. Methods: Microstructure of five dental implant drills using scanning electronic microscopy (SEM) integrated with energy dispersive X-ray spectrometry. Vickers microhardness was measured using a CV 2000 microhardness tester with an indentation force of 500 g. Results: Composition of the implant drills was typical of martensitic stainless steel (MSS). The drills contained 13[%]-17[%] of Cr; Mo, Si and Mn were present as minor ligands. The examined bone drills showed different external surface conformation and hardness in relation to the different industrial production processes. A rougher external surface and a higher hardness value are characteristics of the surgical bone drills produced by hot forming; the implant drills produced by machining showed ma
Ключевые слова:
Bone drill chemical composition; Dental implant drill; Drill hardness; Microstructural surface analysis
Bone; Chemical analysis; Conformations; Dental cutting tools; Drills; Hot stamping; Implants (surgical); Infill drilling; Microhardness; Microstructure; Surface analysis; Surgery; Chemical compositions; Clinical performance; Comparative analysis; Energy dispersive X-ray spectrometry; Industrial production; Micro-structural; Scanning electronic microscopy (SEM); Vickers microhardness; Dental prostheses
Язык текста: Английский
ISSN: 1996-1944
Marenzi G.
Sammartino J. C.
Scherillo F.
Rengo C.
Rosa A. D.
Graziano V.
Spanyuolo D. Dzhanriko 1972-
Марензи Г.
Саммартино Й. C.
Счерилло Ф.
Ренго C.
Роса А. Д.
Гразиано В.
Спанюоло Д. Джанрико 1972-
Comparative analysis of the chemical composition and microstructure conformation between different dental implant Bone Drills
Текст визуальный непосредственный
Materials
MDPI AG
Vol.12, Issue11 P. 1866
2019
Статья
Bone drill chemical composition Dental implant drill Drill hardness Microstructural surface analysis
Bone Chemical analysis Conformations Dental cutting tools Drills Hot stamping Implants (surgical) Infill drilling Microhardness Microstructure Surface analysis Surgery Chemical compositions Clinical performance Comparative analysis Energy dispersive X-ray spectrometry Industrial production Micro-structural Scanning electronic microscopy (SEM) Vickers microhardness Dental prostheses
Background: Hardness is considered an important parameter for evaluating the clinical performance of dental implant bone drills. It is connected to the chemical composition, microstructure conformation and manufacture of the surgical drills. Methods: Microstructure of five dental implant drills using scanning electronic microscopy (SEM) integrated with energy dispersive X-ray spectrometry. Vickers microhardness was measured using a CV 2000 microhardness tester with an indentation force of 500 g. Results: Composition of the implant drills was typical of martensitic stainless steel (MSS). The drills contained 13[%]-17[%] of Cr; Mo, Si and Mn were present as minor ligands. The examined bone drills showed different external surface conformation and hardness in relation to the different industrial production processes. A rougher external surface and a higher hardness value are characteristics of the surgical bone drills produced by hot forming; the implant drills produced by machining showed ma