The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo
Byakova S. F., Novozhilova N. E., Makeeva I. M., Grachev V. I., Kasatkina I. V.
International Endodontic Journal
Vol.52, Issue9, P. 1255-1263
Опубликовано: 2019
Тип ресурса: Статья
Аннотация:
Aim: To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology: Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results: The average sensitivity of CBCT for the diagnosis of VRFs was 0.84
Ключевые слова:
cone-beam computed tomography; diagnosis; vertical root fracture
cone beam computed tomography; human; root canal obturation; tooth fracture; tooth root; Cone-Beam Computed Tomography; Humans; Root Canal Obturation; Spiral Cone-Beam Computed Tomography; Tooth Fractures; Tooth Root
Язык текста: Английский
ISSN: 1365-2591
Byakova S. F. Svetlana Fedorovna 1975-
Novozhilova N. E. Nina Evgenyevna 1985-
Makeeva I. M. Irina Mikhaylovna 1963-
Grachev V. I.
Kasatkina I. V.
Бякова С. Ф. Светлана Федоровна 1975-
Новожилова Н. Е. Нина Евгеньевна 1985-
Макеева И. М. Ирина Михайловна 1963-
Грачев В. И.
Касаткина И. В.
The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo
Текст визуальный непосредственный
International Endodontic Journal
John Wiley & Sons, Inc.
Vol.52, Issue9 P. 1255-1263
2019
Статья
cone-beam computed tomography diagnosis vertical root fracture
cone beam computed tomography human root canal obturation tooth fracture tooth root Cone-Beam Computed Tomography Humans Root Canal Obturation Spiral Cone-Beam Computed Tomography Tooth Fractures Tooth Root
Aim: To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology: Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results: The average sensitivity of CBCT for the diagnosis of VRFs was 0.84