Near-infrared molecular imaging of glioblastoma by miltuximab®-IRDye800CW as a potential tool for fluorescence-guided surgery
Polikarpov D. M., Campbell D. H., McRobb L. S., Wu J., Lund M. E., Lu Y., Deev S. M., Davidson A. S., Walsh B. J., Zvyagin A. V., Gillatt D. A.
Cancers
Vol.12, Issue4, Num.984
Опубликовано: 2020
Тип ресурса: Статья
DOI:10.3390/cancers12040984
Аннотация:
Glioblastoma (GBM) is one of the most aggressive tumors and its 5-year survival is approximately 5[%]. Fluorescence-guided surgery (FGS) improves the extent of resection and leads to better prognosis. Molecular near-infrared (NIR) imaging appears to outperform conventional FGS, however, novel molecular targets need to be identified in GBM. Proteoglycan glypican-1 (GPC-1) is believed to be such a target as it is highly expressed in GBM and is associated with poor prognosis. We hypothesize that an anti-GPC-1 antibody, Miltuximab®, conjugated with the NIR dye, IRDye800CW (IR800), can specifically accumulate in a GBM xenograft and provide high-contrast in vivo fluorescent imaging in rodents following systemic administration. Miltuximab® was conjugated with IR800 and intravenously administered to BALB/c nude mice bearing a subcutaneous U-87 GBM hind leg xenograft. Specific accumulation of Miltuximab®-IR800 in subcutaneous xenograft tumor was detected 24 h later using an in vivo fluorescence i
Ключевые слова:
Brain neoplasm; Fluorescence-guided surgery; Glypican-1; IRDye800CW; Miltuximab; Molecular imaging; Monoclonal antibodies
diagnostic agent; fluorescent dye; immunoglobulin G; immunoglobulin G irdye800cw; ir 800; irdye800cw; miltuximab; miltuximab irdye800cw; monoclonal antibody; unclassified drug; animal experiment; animal model; animal tissue; Article; BALB/c nude mouse; bioaccumulation; cancer surgery; conjugation; contrast enhancement; controlled study; drug distribution; ex vivo study; female; fluorescence guided surgery; fluorescence imaging; glioblastoma; human; human cell; molecular imaging; mouse; near infrared molecular imaging; nonhuman; tumor to background ratio; tumor xenograft; U-87MG ATCC cell line
Язык текста: Английский
ISSN: 2072-6694
Polikarpov D. M.
Campbell D. H.
McRobb L. S.
Wu J.
Lund M. E.
Lu Y.
Deev S. M. Sergej Mikhaylovich 1951-
Davidson A. S.
Walsh B. J.
Zvyagin A. V. Andrej Vasilyevich 1961-
Gillatt D. A.
Поликарпов Д. М.
Cампбелл Д. Х.
МcРобб Л. С.
Wу Й.
Лунд М. Е.
Лу Y.
Деев С. М. Сергей Михайлович 1951-
Давидсон А. С.
Wалш Б. Й.
Звягин А. В. Андрей Васильевич 1961-
Гиллатт Д. А.
Near-infrared molecular imaging of glioblastoma by miltuximab®-IRDye800CW as a potential tool for fluorescence-guided surgery
Текст визуальный непосредственный
Cancers
Vol.12, Issue4 Num.984
2020
Статья
Brain neoplasm Fluorescence-guided surgery Glypican-1 IRDye800CW Miltuximab Molecular imaging Monoclonal antibodies
diagnostic agent fluorescent dye immunoglobulin G immunoglobulin G irdye800cw ir 800 irdye800cw miltuximab miltuximab irdye800cw monoclonal antibody unclassified drug animal experiment animal model animal tissue Article BALB/c nude mouse bioaccumulation cancer surgery conjugation contrast enhancement controlled study drug distribution ex vivo study female fluorescence guided surgery fluorescence imaging glioblastoma human human cell molecular imaging mouse near infrared molecular imaging nonhuman tumor to background ratio tumor xenograft U-87MG ATCC cell line
Glioblastoma (GBM) is one of the most aggressive tumors and its 5-year survival is approximately 5[%]. Fluorescence-guided surgery (FGS) improves the extent of resection and leads to better prognosis. Molecular near-infrared (NIR) imaging appears to outperform conventional FGS, however, novel molecular targets need to be identified in GBM. Proteoglycan glypican-1 (GPC-1) is believed to be such a target as it is highly expressed in GBM and is associated with poor prognosis. We hypothesize that an anti-GPC-1 antibody, Miltuximab®, conjugated with the NIR dye, IRDye800CW (IR800), can specifically accumulate in a GBM xenograft and provide high-contrast in vivo fluorescent imaging in rodents following systemic administration. Miltuximab® was conjugated with IR800 and intravenously administered to BALB/c nude mice bearing a subcutaneous U-87 GBM hind leg xenograft. Specific accumulation of Miltuximab®-IR800 in subcutaneous xenograft tumor was detected 24 h later using an in vivo fluorescence i