Determination of phosphatidylethanol 16:0/18:1 in whole blood by 96-well supported liquid extraction and UHPLC-MS/MS
Berg T., Eliassen E., Jørgenrud B., Kabashi S., Petukhov A. E., Bogstrand S. T.
Journal of Clinical Laboratory Analysis
Vol.33, Issue1, Num.e22631
Опубликовано: 2019
Тип ресурса: Статья
Аннотация:
Background: Phosphatidylethanols (PEths) are specific, direct alcohol biomarkers that can be determined in human blood to distinguish between heavy and social drinking. PEth 16:0/18:1 is among the most predominant PEth homologues in human blood. The aim of the study was to develop a high throughput and sensitive UHPLC-MS/MS method for the determination of PEth 16:0/18:1 in whole blood. Methods: Whole blood samples were prepared by 96-well supported liquid extraction (SLE). Extracted samples were analyzed for PEth 16:0/18:1 by reversed phase UHPLC-MS/MS. Results: The developed UHPLC-MS/MS method was fully validated in whole blood with PEth 16:0/18:1-D 5 as internal standard. Intermediate precision and intermediate accuracy were within ≤± 12[%] and ≤± 17[%], respectively, at PEth 16:0/18:1 concentrations of 1.4-2112 ng/mL (2.0-3004 nmol/L). Limit of quantification (LOQ) was 1.7 ng/mL (2.4 nmol/L). Conclusion: For the first time, 96-well SLE was used for preparation of a PEth homologue in bio
Ключевые слова:
96-well supported liquid extraction; Alcohol; LC-MS/MS; PEth 16:0/18:1; phosphatidylethanol
2 propanol; acetic acid ethyl ester; alcohol; biological marker; heptane; phosphatidylethanol; tert butyl methyl ether; unclassified drug; glycerophospholipid; phosphatidylethanol; Article; blood analysis; calibration; extraction; human; limit of detection; limit of quantitation; liquid chromatography-mass spectrometry; measurement accuracy; measurement precision; blood; chemistry; drinking behavior; high performance liquid chromatography; high throughput screening; isolation and purification; liquid liquid extraction; procedures; reproducibility; tandem mass spectrometry; Alcohol Drinking; Chromatography, High Pressure Liquid; Glycerophospholipids; High-Throughput Screening Assays; Humans; Limit of Detection; Liquid-Liquid Extraction; Reproducibility of Results; Tandem Mass Spectrometry
Язык текста: Английский
ISSN: 1098-2825
Berg T.
Eliassen E.
Jørgenrud B.
Kabashi S.
Petukhov A. E. Aleksej Evgenyevich 1985-
Bogstrand S. T.
Берг Т.
Елиассен Е.
Йøргенруд Б.
Кабаши С.
Петухов А. Е. Алексей Евгеньевич 1985-
Богстранд С. Т.
Determination of phosphatidylethanol 16:0/18:1 in whole blood by 96-well supported liquid extraction and UHPLC-MS/MS
Текст визуальный непосредственный
Journal of Clinical Laboratory Analysis
John Wiley & Sons
Vol.33, Issue1 Num.e22631
2019
Статья
96-well supported liquid extraction Alcohol LC-MS/MS PEth 16:0/18:1 phosphatidylethanol
2 propanol acetic acid ethyl ester alcohol biological marker heptane phosphatidylethanol tert butyl methyl ether unclassified drug glycerophospholipid phosphatidylethanol Article blood analysis calibration extraction human limit of detection limit of quantitation liquid chromatography-mass spectrometry measurement accuracy measurement precision blood chemistry drinking behavior high performance liquid chromatography high throughput screening isolation and purification liquid liquid extraction procedures reproducibility tandem mass spectrometry Alcohol Drinking Chromatography, High Pressure Liquid Glycerophospholipids High-Throughput Screening Assays Humans Limit of Detection Liquid-Liquid Extraction Reproducibility of Results Tandem Mass Spectrometry
Background: Phosphatidylethanols (PEths) are specific, direct alcohol biomarkers that can be determined in human blood to distinguish between heavy and social drinking. PEth 16:0/18:1 is among the most predominant PEth homologues in human blood. The aim of the study was to develop a high throughput and sensitive UHPLC-MS/MS method for the determination of PEth 16:0/18:1 in whole blood. Methods: Whole blood samples were prepared by 96-well supported liquid extraction (SLE). Extracted samples were analyzed for PEth 16:0/18:1 by reversed phase UHPLC-MS/MS. Results: The developed UHPLC-MS/MS method was fully validated in whole blood with PEth 16:0/18:1-D 5 as internal standard. Intermediate precision and intermediate accuracy were within ≤± 12[%] and ≤± 17[%], respectively, at PEth 16:0/18:1 concentrations of 1.4-2112 ng/mL (2.0-3004 nmol/L). Limit of quantification (LOQ) was 1.7 ng/mL (2.4 nmol/L). Conclusion: For the first time, 96-well SLE was used for preparation of a PEth homologue in bio