Comparison of cord blood lactate measurement by gas analyzer and portable electrochemical devices
Romanov A. Y., Prikhodko A. M., Tysyachnyi O. V., Baev O. R., Yarotskaya E. L., Sukhikh G. T.
Journal of Perinatal Medicine
Vol.48, Issue2, P. 157-161
Опубликовано: 2020
Тип ресурса: Статья
DOI:10.1515/jpm-2019-0357
Аннотация:
To compare the accuracy of cord blood lactate measurement using gas analyzer and portable devices in order to assess possibility of implementation of these devices in clinical practice. We performed a prospective observational study using 30 umbilical cord samples which were obtained immediately after birth. Portable electrochemical devices Lactate Scout (SensLab GmbH, Leipzig, Germany) and StatStrip Lactate (NOVA Biomedical, Waltham, MA, USA) were used to determine lactate level. A gas analyzer ABL800 FLEX (Radiometer Medical ApS, Brønshøj-Husum, Denmark) was used as a reference. Base excess (BE), pH, partial oxygen (pO2) and carbon dioxide (pCO2) pressure, hemoglobin (ctHb) and bilirubin (ctBl) levels were measured. The mean umbilical cord blood lactate level determined by the gas analyzer was 5.85 ± 2.66 mmol/L (ranging from 1.4 mmol/L to 13.4 mmol/L). Lactate level estimated by Lactate Scout was 5.66 ± 2.65 mmol/L and did not significantly differ from the reference method level (P
Ключевые слова:
acid base status; base excess; cord blood lactate; fetal hypoxia; gas analyzer; labor; partial carbon dioxide pressure; partial oxygen pressure; pH
bilirubin; hemoglobin; lactic acid; alkalosis; Article; blood gas analysis; blood pH; carbon dioxide tension; clinical decision making; clinical practice; controlled study; diagnostic accuracy; electrochemical analysis; human; intermethod comparison; lactate blood level; measurement accuracy; observational study; oxygen tension; priority journal; prospective study; reference value; umbilical cord blood
Язык текста: Английский
ISSN: 1619-3997
Romanov A. Y.
Prikhodko A. M.
Tysyachnyi O. V.
Baev O. R. Oleg Radomirovich 1957-
Yarotskaya E. L.
Sukhikh G. T. Gennadij Tikhonovich 1947-
Романов А. Y.
Приходко А. М.
Тyсячнyи О. В.
Баев О. Р. Олег Радомирович 1957-
Яроцкайа Е. Л.
Сухих Г. Т. Геннадий Тихонович 1947-
Comparison of cord blood lactate measurement by gas analyzer and portable electrochemical devices
Текст визуальный непосредственный
Journal of Perinatal Medicine
Walter de Gruyter GmbH
Vol.48, Issue2 P. 157-161
2020
Статья
acid base status base excess cord blood lactate fetal hypoxia gas analyzer labor partial carbon dioxide pressure partial oxygen pressure pH
bilirubin hemoglobin lactic acid alkalosis Article blood gas analysis blood pH carbon dioxide tension clinical decision making clinical practice controlled study diagnostic accuracy electrochemical analysis human intermethod comparison lactate blood level measurement accuracy observational study oxygen tension priority journal prospective study reference value umbilical cord blood
To compare the accuracy of cord blood lactate measurement using gas analyzer and portable devices in order to assess possibility of implementation of these devices in clinical practice. We performed a prospective observational study using 30 umbilical cord samples which were obtained immediately after birth. Portable electrochemical devices Lactate Scout (SensLab GmbH, Leipzig, Germany) and StatStrip Lactate (NOVA Biomedical, Waltham, MA, USA) were used to determine lactate level. A gas analyzer ABL800 FLEX (Radiometer Medical ApS, Brønshøj-Husum, Denmark) was used as a reference. Base excess (BE), pH, partial oxygen (pO2) and carbon dioxide (pCO2) pressure, hemoglobin (ctHb) and bilirubin (ctBl) levels were measured. The mean umbilical cord blood lactate level determined by the gas analyzer was 5.85 ± 2.66 mmol/L (ranging from 1.4 mmol/L to 13.4 mmol/L). Lactate level estimated by Lactate Scout was 5.66 ± 2.65 mmol/L and did not significantly differ from the reference method level (P