Robustness of serologic investigations for Chikungunya and Mayaro viruses following coemergence
Fischer C., Bozza F., Merino X. J. M., Pedroso C., Filho E. F. O., Moreira-Soto A., Schwalb A., de L. X., Netto E. M., Bozza P. T., Sarno M., Brites C., Gotuzzo E., Talledo M., Doktor D. Ya. F.
mSphere
Vol.5, Issue1, Num.e00915
Опубликовано: 2020
Тип ресурса: Статья
DOI:10.1128/mSphere.0915-19
Аннотация:
Since 2013, the arthropod-borne Chikungunya virus (CHIKV) has cocirculated with the autochthonous Mayaro virus (MAYV) in Latin America. Both belong to the same alphavirus serocomplex, termed the Semliki Forest serocomplex. The extent of antibody cross-reactivity due to the antigenic relatedness of CHIKV and MAYV in commonly used serologic tests remains unclear. By testing 64 CHIKV-and 37 MAYV-specific sera from cohort studies conducted in Peru and Brazil, we demonstrate about 50[%] false-positive test results using commercially available enzymelinked immunosorbent assays (ELISAs) based on structural antigens. In contrast, combining ELISAs for CHIKV and MAYV significantly increased positive predictive values (PPV) among all cohorts from 35.3[%] to 88.2[%] for IgM and from 61.3[%] to 96.8[%] for IgG (P<0.0001). Testing of longitudinally collected CHIKV-specific patient sera indicated that ELISA specificity is highest for IgM testing at 5 to 9 days post-onset of symptoms (dpo) and for IgG testing a
Ключевые слова:
Arbovirus diagnostics; Brazil; Cross-reactivity; ELISA; Mosquito-borne disease; Outbreak; Peru; Serology
immunoglobulin M; neutralizing antibody; immunoglobulin G; adolescent; adult; antigenicity; Article; Brazil; Chikungunya virus; cohort analysis; controlled study; cross reaction; enzyme linked immunosorbent assay; female; human; major clinical study; male; Mayaro virus; molecular phylogeny; nonhuman; Peru; predictive value; seroconversion; serology; virus neutralization; virus transmission; antibody detection; antigen structure; diagnostic accuracy; false positive result; seroepidemiology
Язык текста: Английский
ISSN: 2379-5042
Fischer C.
Bozza F.
Merino X. J. M.
Pedroso C.
Filho E. F. O.
Moreira-Soto A.
Schwalb A.
de L. X. Lamballerie X.
Netto E. M.
Bozza P. T.
Sarno M.
Brites C.
Gotuzzo E.
Talledo M.
Doktor D. Ya. F. Dreksler Yan Feliks 1976-
Фисчер C.
Бозза Ф.
Мерино Х. Й. М.
Педросо C.
Филхо Е. Ф. О.
Мореира-Сото А.
Счwалб А.
де Л. Х. Ламбаллерие Х.
Нетто Е. М.
Бозза П. Т.
Сарно М.
Бритес C.
Готюззо Е.
Талледо М.
Доктор Д. Я. Ф. Дрекслер Ян Феликс 1976-
Robustness of serologic investigations for Chikungunya and Mayaro viruses following coemergence
Текст визуальный непосредственный
mSphere
American Society for Microbiology
Vol.5, Issue1 Num.e00915
2020
Статья
Arbovirus diagnostics Brazil Cross-reactivity ELISA Mosquito-borne disease Outbreak Peru Serology
immunoglobulin M neutralizing antibody immunoglobulin G adolescent adult antigenicity Article Brazil Chikungunya virus cohort analysis controlled study cross reaction enzyme linked immunosorbent assay female human major clinical study male Mayaro virus molecular phylogeny nonhuman Peru predictive value seroconversion serology virus neutralization virus transmission antibody detection antigen structure diagnostic accuracy false positive result seroepidemiology
Since 2013, the arthropod-borne Chikungunya virus (CHIKV) has cocirculated with the autochthonous Mayaro virus (MAYV) in Latin America. Both belong to the same alphavirus serocomplex, termed the Semliki Forest serocomplex. The extent of antibody cross-reactivity due to the antigenic relatedness of CHIKV and MAYV in commonly used serologic tests remains unclear. By testing 64 CHIKV-and 37 MAYV-specific sera from cohort studies conducted in Peru and Brazil, we demonstrate about 50[%] false-positive test results using commercially available enzymelinked immunosorbent assays (ELISAs) based on structural antigens. In contrast, combining ELISAs for CHIKV and MAYV significantly increased positive predictive values (PPV) among all cohorts from 35.3[%] to 88.2[%] for IgM and from 61.3[%] to 96.8[%] for IgG (P<0.0001). Testing of longitudinally collected CHIKV-specific patient sera indicated that ELISA specificity is highest for IgM testing at 5 to 9 days post-onset of symptoms (dpo) and for IgG testing a